View specification sheet in Adobe PDF format.

Tilt Table

Left24.2°
Right27.0°

Braking

 10 mph 17mph
Skid Pad4.4 feet14.8 feet
Gravel5.816.3 feet

Slope Climbing

  ForwardReverseStart, Shut Down, Descend
40%21.8°YesYesYes
50%26.6°YesYesYes
60%31.0°YesYesYes

Tractive Effort Pulled Puckup Truck through soft sand

Off-Road Tire EMT Mud RunnerPassed

Air Conditioning Testing

Dometic Environmental Chamber - La Grange, IN

Tested July 28, 2008 - Overnight Temperature : 108°F - Maintained Overnight

Cooling TimeCabPatient Compartment
Beg. Temp110.6°111.58°
1 Hour110.6°84.38°
2 Hours82.6°79.90°
3 Hours81.3°79.40°
4 Hours78.6°78.60°